Fire Alarm & Fire Survival Cables
- Home
- Fire Alarm & Fire Survival Cables
Fire Alarm & Fire Survival Cables
Fire alarm cables for highest safety requirements
Applications
Cables to maintain power supplies and data transmission to fire alarm system,public adress and voice alarm systems.
Indoor for:
Audio Circuits
Control Circuits
Initiating Circuits
Notification Circuits
FIRE ALARM CABLES (300 V)
Construction:
Solid/Stranded plain copper conductor, PVC insulation, metallic barrier, tinned copper earth conductor & FRLS PVC Sheathed.
| Part No. | Cores × mm² | Colour | O/D (mm) |
|---|---|---|---|
| PSFRS215R | 2 × 1.5 | Red | 7.7 |
| PSFRS215W | 2 × 1.5 | White | 7.7 |
| PSFRS415R | 4 × 1.5 | Red | 9.2 |
| PSFRS415W | 4 × 1.5 | White | 9.2 |
| PSFRS225R | 2 × 2.5 | Red | 8.9 |
| PSFRS225W | 2 × 2.5 | White | 8.9 |
| PSFRS425R | 4 × 2.5 | Red | 10.9 |
| PSFRS425W | 4 × 2.5 | White | 10.9 |
FIRE SURVIVAL CABLES
It is now recognised that in some buildings the continued functioning or circuit integrity of some cables are essential in providing sufficient time for evacuation.
These Enhanced version cables shown below are suitable for installation where evacuation may be
delayed, for example in hospitals or high-rise buildings without sprinklers. The ‘enhanced’ group of
cables offer a viable alternative to MICC (Mineral Insulated Copper Clad) in many applications with the
benefit of faster installation and easier routing.
These collection of cables are also popular on overground railways, other transport systems and other ommercial applications where fire and smoke propagation are critical factors.
Applications range from radio communications to alarm and emergency evacuation circuits.
Construction:
Solid plain copper conductor, Mica tape, silicone rubber insulation, metallic barrier, tinned
copper earth conductor & enhanced low smoke halogen free sheath.
| Part No. | Cores × mm² | Colour | O/D (mm) |
|---|---|---|---|
| PSFSS215R | 2 × 1.5 | Red | 8.6 |
| PSFSS215W | 2 × 1.5 | White | 8.6 |
| PSFSS415R | 4 × 1.5 | Red | 10.1 |
| PSFSS415W | 4 × 1.5 | White | 10.1 |
| PSFSS225R | 2 × 2.5 | Red | 9.9 |
| PSFSS225W | 2 × 2.5 | White | 9.9 |
| PSFSS425R | 4 × 2.5 | Red | 11.9 |
| PSFSS425W | 4 × 2.5 | White | 11.9 |
| Standards As Per |
|---|
| BS 5839-1:2002 Clause 26.2(e) Enhanced |
| BS 8434-2:2003 |
| BS EN 50200 PH120 |
| BS 6387 C, W & Z |
| IEC 60332-3 |
| IEC 60332-1 |
| BS EN 50265 |
| BS EN 50266 |
| IEC 60754 |
| BS EN 50267 |
| IEC 61034 |
| BS EN 50268 |